Services

Capabilities, from Land Assessment to Long‑Term Operations

Site assessment, fuel supply contracts, grid and permits, EPC and commissioning, and long-term operation for small-scale wood biomass CHP projects in Japan.

Who this works for

Forestry suppliers: A steady, contracted buyer for low-grade material that otherwise has no market. Long-term offtake gives thinning operations, including forestry cooperatives, a more predictable revenue stream.

Sawmills: Bark, sawdust, and offcuts become a revenue stream instead of a disposal cost. Nearby process heat can also support drying and other mill operations.

Municipalities: Energy revenue pays for part of the forest maintenance alongside public budgets. A local plant also supports jobs and regional resilience.

Heat users: Nearby industry and facilities gain access to predictable, locally generated heat. The heat is made from wood supplied within the area.

Investors & partners: Each project is small-unit and repeatable, with its fuel supply secured before construction. That combination reduces both fuel risk and permitting complexity compared with utility-scale biomass.

Land identification & assessment

Identifying candidate sites and assessing them against forestry catchment, access, and site conditions before a project is defined.

Feedstock & site screening

Evaluating whether a site's likely wood volumes, access, and forestry activity can support a fuel-tolerant CHP unit over the long term.

Fuel-chain development

Building durable local supply relationships with forestry suppliers, thinning operators, and sawmills so fuel is secured by multi-year contracts.

Supplier coordination

Coordinating logistics, delivery schedules, and material specifications across forestry crews, stockyards, and sawmills feeding a project.

Utility & regulatory coordination

Managing grid interconnection, permitting, and the local regulatory steps a forestry-fed biomass project needs to move forward.

EPC & commissioning

Coordinating engineering, procurement, and construction of the CHP unit and site infrastructure, through to startup and commissioning.

Technology integration

Matching the CHP system to the site's actual fuel and its heat and power demand.

Long-term operations support

Ongoing monitoring, maintenance coordination, and performance support after commissioning, sized for a low-staffing, remotely monitored unit.

Project-development support

Structuring the project timeline, stakeholders, and documentation from initial concept through to operating asset.

01 — Site & feasibility

We identify candidate sites and assess land, forestry catchment, and access before committing to a project.

Chipping and drying — raw logs becoming generator-ready fuel (concept rendering)

02 — Permits & agreements

We manage grid interconnection, permitting, and the local regulatory steps a project needs to move forward.

03 — Fuel-chain contracts

We build supply agreements with forestry suppliers and sawmills so the project's fuel is under contract.

04 — EPC & commissioning

We coordinate engineering, procurement, and construction of the CHP unit through to startup and commissioning.

05 — Operations & fuel logistics

We support ongoing O&M, fuel logistics, and monitoring once the plant is running.

Contracted heat for industry

The unit behind every figure

One block, on your land

Three LiPRO HKW300 units run in cascade, one CFD dryer, and one moving-floor fuel bay.

300kWe
Electric, rated
At the genset — the 4% self-use below is the only reduction applied.
696kWth
Thermal, installed
85–100 °C hot water.
~2,304MWh-e
Electricity a year
Net to site — ~2,400 generated, less ~4% internal self-use.
452kWth
Heat, deliverable
After the 35% drying self-draw from the 696 kWth installed.
~3,600t/yr
Chips a year
As-received, ~50% moisture.
~0.25–0.4ha
Footprint

Reference design — design figures from the manufacturer specification and our published model, not measurements from an operating plant. No project is sited or in progress. This three-unit reference block is a distinct configuration from the ten-unit data-center block.

Inside the LiPRO HKW300 — the combined heat-and-power unit's core equipment (official manufacturer material)
Source: LiPRO manufacturer material

We deliver woody heat at typically around half the useful cost of Class-A heavy oil, on a zero-capex ESCO basis. The oil side runs about ~¥14 per kWh_th (Class-A heavy oil at an illustrative ¥132.4/L ÷ 9.45 kWh_th/L); your number comes from the assessment. You pay per unit of heat below oil parity; your existing oil boiler stays as backup, so reliability never depends on us alone.

The fit test is simple: about 100 °C hot water and ~452 kWth deliverable (696 kWth installed; ≈452 kWth deliverable after the fuel-drying draw). That suits food processing, brewing, laundry, greenhouse, aquaculture, and onsen loads — the qualifying question is whether your temperature and year-round load match. The minimum viable case starts from about 150 kW of sustained heat — one unit delivers ~151 kWth; below that, a smaller boiler fits better.

The fit varies by load. An onsen or ryokan runs a strong overnight and seasonal demand curve; on-site laundry is a separate, steadier load that our ~90–100 °C water matches directly. We size the block to your measured demand profile.

Siting is discreet by design: chip deliveries run to a modest cadence of a few a week, and the fuel bay and block sit on host or adjacent land, away from guest-facing areas.

Maintenance is carried out by manufacturer-trained technicians under the service agreement. Because your oil boiler stays in place as backup, you keep two heat sources but pay only for the woody heat you draw — reliability never rests on us alone. The contract states its term, exit terms, and equipment ownership up front; if Analema were unable to continue, the heat-supply contract and the equipment carry assignment provisions.

The order of magnitude is a Scope-1 cut of ~1,040 t-CO2/yr (illustrative), from burning local wood in place of fossil fuel.

Figures are illustrative, on the assumptions above. We hold no named process-heat references yet; the case stands on price and fit, and we compute your number against your own oil bill.